Filter Results By:

Products

Applications

Manufacturers

Showing results: 16 - 29 of 29 items found.

  • Dosimeter-Radiometer

    MKS-05 - Ecotest

    In comparison with MKS-05 "TERRA-P" dosimeter-radiometer for household use, "TERRA-P+" has new features:wider measurement range of gamma radiation ambient dose equivalent rate;measurement of surface beta-particles flux density;measurement of ambient dose equivalent accumulation time;automatic subtraction of gamma background at measurement of beta contamination;

  • Materials And Chemical Analysis

    Anderson Materials Evaluation, Inc.

    Materials characterization, failure analysis, quality control, and materials and process development services are offered.  Our analytical techniques allow us to assess elemental and chemical material composition, thermal properties, coating thickness, electrochemical properties, surface chemistry, surface wetting, corrosion rates and pitting potentials, contamination and degradation problems, metallography, fractography, phase transitions, static coefficient of friction, adhesive bonding strength and causes of adhesive bonding failures, surface tension and surface energy, tensile and compressive strength, bend deflection, lapshear strength, elasticity properties, UV and visible light absorption and reflection, density and porosity, and many other material properties integral to improving your products.

  • Analytical Techniques

    Anderson Materials Evaluation, Inc.

    Our numerous analytical techniques, we tackle a wide range of materials challenges and commonly combines several analytical techniques to fully address complex and multi-dimensional materials issues.  Our materials analysis laboratory provides XPS surface analysis, thermal analysis (TGA, DSC, TMA), FTIR infrared spectroscopy, UV-Vis spectrophotometry and reflectivity measurements, gas chromatography – mass spectroscopy (GC-MS), SEM/EDX, optical microscopy, mechanical testing, electrochemistry and corrosion analyses, residual gas mass spectroscopy, contact angle measurements, surface contamination measurements, adhesive bonding failure analysis, facility testing for silicone contamination, mechanical testing, metallography and fractography, density and porosity measurements, volatile organic component testing, friction, and other analytical capabilities.  We continue to upgrade and expand our arsenal of analytical techniques and custom analytical methods to support our customers’ needs.

  • Chemical Testing

    Accolade Engineering Solutions

    To ensure product environmental compliance or to gain better understanding of your materials or processes, chemical testing is often required. AES has state of the art the equipment for chemical analysis. For elemental analysis XRF, SEM/EDS or ICP can be used. For molecular analysis GCMS, HPLC and FTIR may be used. FTIR may also be used for surface analysis of contamination and our microFTIR system is suitable for the smallest samples.

  • TTC-1 Tracking Test Chamber

    TTC-1 - Lisun Electronics Inc.

    It is according to IEC60695 and IEC60112 (GB4207), the Tracking Test Chamber TTC-1 is intended for determining the degree of protection against formation of conducting paths in solid insulating materials, due to the electric stress and electrolytic contamination of the surface. This method simulates tracking currents on insulation material by providing drops between electrodes. During the process of normal use, insulating material may be exposed to moisture and dirt, if conductive, may cause stress and fire hazard.

  • Optical 12,000 Meter Connector

    Teledyne Marine Impulse-PDM

    ​Teledyne Impulse-PDM’s 5135/5175 optical connectors utilize proven standard ferrule technology and are available for multi-mode or single-mode operation.The connectors are manufactured in Titanium Ti 6Al-4V, which is electro-polished to remove surface contamination, thus improving resistance to corrosion. The engaging nuts are also manufactured in the same grade of Titanium and the threads are coated with a Nickel/PTFE composite coating to prevent galling. The connectors have been qualifi ed to 12,000 meter operating depth.

  • Omicron Fiber Optic Connector

    Teledyne Marine Impulse-PDM

    Teledyne Impulse-PDM’s Omicron 5030/5070 optical connectors utilize proven small form factor ferrule technology and are available for multi-mode or single-mode operation.The connectors are offered, as standard, in stainless steel to BSEN10088-3 Grade 1.4404 (316L), which is electro-polished to remove surface contamination, thus improving resistance to corrosion. Connector bodies can also be manufactured in other materials, either to address specific anti-corrosion requirements, or to increase depth rating. Engaging nuts are normally manufactured in naval brass to UNS C46400​.

  • Pulse AC Method Area Ionizers

    ER-X Series - Panasonic Industrial Devices Sales Company of America

    The ER-X Series Area Ionizers utilize the pulse AC ionization design to achieve high-speed charge removal of wide surface areas for high-volume production lines. In addition to supporting compressed air ionization, the ER-X also features both airless and low-pressure ionization modes for applications where tiny workpieces can be easily blown away. Additional features include automatic ion balance and discharge frequency control (manual control is also possible), flat discharge surface for easy cleaning, discharge needle air barrier design to reduce contamination of the needles, replaceable discharge needle unit for easy maintenance, and a dual head configuration for enhanced charge area and layout (2 different ionizer heads can be connected to a single controller).

  • Certified Sanitary Inline Refractometer | 2″ Tri-Clamp

    VIP2-3A - MISCO Refractometer

    3-A Sanitary Refractometer for Food & Product Safety: Driven by concerns over food and product safety in the dairy, food, beverage, and bio-pharmaceutical industries, 3-A certified sanitary refractometers must meet exacting hygienic standards before they are awarded certification, one of the top honors attainable in the field of refractometry. Needless to say, refractometers carrying the 3-A seal meet the highest level of professional standards for the protection of public health by offering the maximum degree of protection against food or product contamination, resulting in product contact surfaces that can be easily cleaned and sanitized.

  • Geiger Counter

    ONYX® - International Medcom

    ONYX features a modern, streamlined look and the use of advanced technologies, making it a one-of-a-kind Geiger Counter. It weighs only 7 oz. (200g.) and measures a mere 5.1 X 2.6 X 0.9 in. (72 X 37 X 13 mm.) making it easy to transport. Despite its compact size ONYX is capable of detecting alpha, beta and gamma radiation with the same sensitivity as the IMI Inspector Alert™, and like the IMI Inspector Alert™ V2, ONYX is optimized for surface contamination measurements through use of its 2 in. pancake Geiger Mueller tube.

  • Sample Pretreatment For Optical Emission Spectrometry

    Shimadzu Corp.

    Samples are taken from molten metal, thin sheet, semi-complete or complete products. When sampling molten metal with a ladle, small quantities of molten metal are poured into a casting mold. Unnecessary parts of the sample are removed using a grinder or a cutter. As particles from a grinder may contaminate the surface of the sample, a lathe or milling machine is used (not a grinder) to cut soft samples such as white metal. If trace elements are not being investigated, a grinder or belt sander can be used. However, to minimize contamination, the grinding wheel or belt should be changed for each sample. Samples excised from semi-complete or complete products must be at least 12 mm in diameter. Small rod-shaped samples can be analyzed using special equipment.

  • Bearing Testers

    Anderon Meters - MOTOMEA

    *Measures the anderon value in an assembled bearing.*Detects slight surface irregularities arising from machining imperfections and other factors.*Detects displacement in a radial direction caused by rolling surface irregularities.*Provides the “anderon” value, a numerical expression of the degree of vibration and noise in the bearing, allows quantitative assessment of bearing performance.*Enables the discovery of the causes of vibrations (scratches on the raceways of outer and inner races made during machining, scratches on ball surfaces, contamination by dust particles, etc.).*Enables the sorting of bearings by precision class and more accurate assessment of bearing quality.*Development of high-quality products: aids in the development of high-quality, durable bearings that generate minimal vibration and noise.*Assurance of product quality: allows data to be gathered that can be used for objective assessment of quality, particularly vibration and noise characteristics.*Optimal management of products by quality: High-sensitivity detection of minute but critical variations in product characteristics, allowing to sort bearings accurately by quality for optimal product management.*Improved productivity: allows inspection of bearings before installation in high-precision, high-performance products susceptible to vibration, minimizing defects in assembled products and improving productivity.*Optimal parts control in the open market environment: permits high-accuracy acceptance inspections of delivered parts, allowing to test various samples obtained from both domestic and overseas manufacturers to help secure parts that offer optimal quality.

  • Capacitive Proximity Sensors

    SICK Sensor Intelligence

    Sometimes you need to know what is hidden beneath a surface. Behind a wall, for example, inside a storage container, inside a shipping container, or behind a cover. Capacitive proximity sensors are ideal for level and feed monitoring. From solid material, such as paper or wood, to granules or liquids, they can be relied upon to detect what is happening in the production process and during final inspection. Is there something behind that cover? Is the finished package really full? How much paint is still left in the tank? For capacitive proximity sensors, these are easy questions to answer. SICKs capacitive proximity sensors are never far from the action. Sensing ranges between 1 and 25 mm allow them to be used in nearly all installation situations, making them extremely adaptable for a wide range of applications. These sensors are also remarkably resistant to interference. Impurities, contamination, dust, and airborne spray particles have little effect on them, nor does electromagnetic interference. No wonder they are installed in a wide range of industries, such as food and automotive, or in storage and conveyor systems.

  • Dial Indicators

    Rhopoint Metrology Ltd

    1. Always select the dial test indicator that best fits the application.2. Care should be taken while using a dial test indicator, try not to jolt the indicator, should you be unfortunate and drop a dial test indicator, get it re-calibrated/repaired before reusing it.3. Replace worn contact points only with those of a similar length from the centre of the ball stylus to the abutment shoulder.4. Always clean dial test indicators after use with a lint free paper or cloth and store the indicator in its box or in a dust free area.5. When using a dial test indicator, always position the dial test indicator in a horizontal plane to the surface media.6. Always use a rigid stand for mounting the dial test indicator.7. When measuring a rotating object, either between centres or in a vee block, ensure that the object is rotating in the correct direction. Never rotate the workpiece towards the contact point.8. When measuring a sliding object, only take readings when the object is moving directly towards the contact point, never away from the contact point or in a sideways manner.9. Avoid parallax errors by reading the dial directly from the front and square on to the dial.10. Never oil a dial test indicator as this attracts contamination, should the movement become erratic then the dial test indicator should be submitted to a reputable repair agent.11. Try not to expose dial test indicators to direct sunlight or in a high humidity environment.12. Never use a dial test indicator that has not been calibrated, if in doubt consult an appropriate authority.

Get Help